Find various drawings of assemblies using NGC products and related data here. |
 |
 |
 |
 |

 |
This list contains 54 entries. Scroll to see all available items.
 |

 |
 |

09250-01 Wall Priority Legend
 |
 |
>
DWG
(43 Kb) >
DXF
(68 Kb) >
GIF
(10 Kb)
|
 |

 |
 |

09250-02 One Hour Fire Partition Perpendicular To Flutes
 |
 |
>
DWG
(57 Kb) >
DXF
(109 Kb) >
GIF
(16 Kb)
|
 |

 |
 |

09250-03 One Hour Fire Partition Perpendicular To Flutes
 |
 |
>
DWG
(69 Kb) >
DXF
(146 Kb) >
GIF
(23 Kb)
|
 |

 |
 |

09250-04 Joint Requirements One Hour Wall
 |
 |
>
DWG
(54 Kb) >
DXF
(110 Kb) >
GIF
(11 Kb)
|
 |

 |
 |

09250-05 Typical Corner Detail
 |
 |
>
DWG
(173 Kb) >
DXF
(474 Kb) >
GIF
(13 Kb)
|
 |

 |
 |

09250-06 One Hour Wall At Exterior Wall
 |
 |
>
DWG
(176 Kb) >
DXF
(480 Kb) >
GIF
(20 Kb)
|
 |

 |
 |

09250-07 Typical Column Detail At Corridor
 |
 |
>
DWG
(140 Kb) >
DXF
(371 Kb) >
GIF
(18 Kb)
|
 |

 |
 |

09250-08 One Hour Fire Wall Under Beam
 |
 |
>
DWG
(48 Kb) >
DXF
(83 Kb) >
GIF
(12 Kb)
|
 |

 |
 |

09250-09 Two Hour Fire Partition Perpendicular To Flute
 |
 |
>
DWG
(75 Kb) >
DXF
(167 Kb) >
GIF
(21 Kb)
|
 |

 |
 |

09250-10 Two Hour Fire Partition Perpendicular To Flute
 |
 |
>
DWG
(97 Kb) >
DXF
(232 Kb) >
GIF
(23 Kb)
|
 |

 |
 |

09250-11 Joint Requirements Two Hour Wall
 |
 |
>
DWG
(88 Kb) >
DXF
(215 Kb) >
GIF
(14 Kb)
|
 |

 |
 |

09250-12 Two Hour Fire Wall Between Patient Room And Stair
 |
 |
>
DWG
(249 Kb) >
DXF
(702 Kb) >
GIF
(20 Kb)
|
 |

 |
 |

09250-13 Fire And/Or Smoke Wall At Exterior Wall
 |
 |
>
DWG
(127 Kb) >
DXF
(329 Kb) >
GIF
(24 Kb)
|
 |

 |
 |

09250-14 Intersection Of Rated Walls
 |
 |
>
DWG
(469 Kb) >
DXF
(1 Mb) >
GIF
(23 Kb)
|
 |

 |
 |

09250-15 Two Hour Fire Wall Under Beam
 |
 |
>
DWG
(60 Kb) >
DXF
(121 Kb) >
GIF
(12 Kb)
|
 |

 |
 |

09250-16 Typical Rated Wall Parallel To Deck
 |
 |
>
DWG
(45 Kb) >
DXF
(75 Kb) >
GIF
(12 Kb)
|
 |

 |
 |

09250-17 Two Hour Fire Wall And Two Hour Fire Wall Within 12" Of Beam
 |
 |
>
DWG
(137 Kb) >
DXF
(356 Kb) >
GIF
(18 Kb)
|
 |

 |
 |

09250-18 Rated Partition Adjacent To Beam
 |
 |
>
DWG
(58 Kb) >
DXF
(109 Kb) >
GIF
(16 Kb)
|
 |

 |
 |

09250-19 Partition Under Beam
 |
 |
>
DWG
(111 Kb) >
DXF
(276 Kb) >
GIF
(19 Kb)
|
 |

 |
 |

09250-20 Rated Partition Adjacent To Beam
 |
 |
>
DWG
(50 Kb) >
DXF
(91 Kb) >
GIF
(14 Kb)
|
 |

 |
 |

09250-21 Rated Partition Adjacent To Beam
 |
 |
>
DWG
(55 Kb) >
DXF
(105 Kb) >
GIF
(15 Kb)
|
 |

 |
 |

09250-22 Gypsum Two Hour Fire Rated Control Joint
 |
 |
>
DWG
(135 Kb) >
DXF
(380 Kb) >
GIF
(14 Kb)
|
 |

 |
 |

09250-23 Control Joint At Door
 |
 |
>
DWG
(27 Kb) >
DXF
(18 Kb) >
GIF
(8 Kb)
|
 |

 |
 |

09250-24 One Hour Deflection Track Perpendicular To Flute
 |
 |
>
DWG
(63 Kb) >
DXF
(141 Kb) >
GIF
(16 Kb)
|
 |

 |
 |

09250-25 Non-Rated Partition At Rated Ceiling
 |
 |
>
DWG
(44 Kb) >
DXF
(72 Kb) >
GIF
(11 Kb)
|
 |

 |
 |

09250-26 Metal Stud Smoke Partition At Con. Block Fire Smoke Partition
 |
 |
>
DWG
(141 Kb) >
DXF
(372 Kb) >
GIF
(19 Kb)
|
 |

 |
 |

09250-27 Walls Perpendicular To Metal Deck Flutes
 |
 |
>
DWG
(62 Kb) >
DXF
(127 Kb) >
GIF
(19 Kb)
|
 |

 |
 |

09250-28 Adjacent Electrical Boxes
 |
 |
>
DWG
(161 Kb) >
DXF
(435 Kb) >
GIF
(16 Kb)
|
 |

 |
 |

09250-29 Rated Drywall Ceilings
 |
|
| |